Next: j_cat_extract Up: Science Data Products Previous: j_gti   Contents

j_dead_time

At this step dead time is calculated. It is saved to JMXi-DEAD-SCP (Table 44) which is stored once for each science window.

Table 44: Content of JMXi-DEAD-SCP Data Structure.
 
Column Name Description
OB_TIME OBT of the dead time calculation
DEADTIME Fractional input dead time not including grey filter losses
RATE_COR Factor for correcting count rates, not including grey filter losses
DEAD_EFF Total effective dead time including grey filter