The executable ibis_isgr_deadtime calculates dead times resulting
from count rates in ISGRI modules, taking into account the instrument configuration.
ISGRI dead time is due to the combined effect of:
- Instrument count rate,
- Veto count rate (from the lateral, or lateral+bottom (according to IC file) shielding),
- Calibration count rate,
- Compton coincidences, if Compton mode is on.
Note that the problem of the VETO swapping on-board is corrected
almost every time through IC file: IBIS-VETO-MOD. VETO also
sometimes has a wrong level; this will be corrected in the future. The 3 cases
when it happened are in the IC file GNRL-INTL-BTI with the BTI_TYPE:
ISGRI_VETO_LEVEL.
Table:
ibis_isgr_deadtime parameters included into the main script.
|
|
|
|
Name |
Name |
Type |
Description |
(in the main script) |
(executable) |
|
|
SCW1_veto_mod |
icDOL |
string |
DOL of the IC file for VETO model and width of Compton window
default `` '' |